A precise understanding of the principles of lung mechanics, gas exchange and control of breathing is a cornerstone for every practitioner in the field of anaesthesia. Understanding these principles helps maintain the patient's optimal oxygenation and ventilation during anaesthesia and surgical operations.
Lung Volumes and Breathing Mechanics
Functional residual capacity (FRC) represents the volume of gas remaining in the lungs at the end of a normal passive expiration, and it is the sum of the expiratory reserve volume and the residual volume (FRC = ERV + RV). Because the residual volume can never be expelled by expiration, FRC cannot be measured with a direct Spirometry device and requires special techniques such as Helium dilution or Body plethysmography. On the other hand, lung compliance is defined as the change in volume per unit change in pressure (ΔV/ΔP); it represents the slope of the pressure-volume curve, and its normal value in the adult respiratory system is about 200 mL/cm H2O.
Perfusion, Ventilation and Gas Exchange
In the upright position, both ventilation and blood flow decrease from the base of the lung to the apex, but blood flow falls more steeply than ventilation, making the ventilation-to-perfusion (V/Q) ratio highest at the apex and lowest at the base. When perfusion is disturbed, the physiological dead space is calculated using the Bohr equation: VD/VT = (PaCO2 − PECO2)/PaCO2. In pulmonary shunt states, the shunt fraction is measured by the equation Qs/Qt = (Cc'O2 − CaO2)/(Cc'O2 − CvO2); hypoxaemia caused by an absolute shunt is characterised by the fact that it cannot be fully corrected or abolished even with 100% O2. To prevent worsening of ventilation-perfusion mismatch, the lung has the mechanism of hypoxic pulmonary vasoconstriction, in which the smooth muscle of the pulmonary arteries contracts in response to a fall in alveolar PO2, intrinsically and independently of systemic nerves, to divert blood away from poorly ventilated alveoli.
Oxygen Transport and Control of Ventilation
P50 expresses the partial pressure of oxygen at which haemoglobin saturation reaches 50%, and its normal value is about 26.8 mm Hg (or 3.6 kPa) in adults. The haemoglobin dissociation curve shifts to the right, increasing P50 and facilitating oxygen release to the tissues, as a result of increased hydrogen ions (a fall in pH), increased PCO2 (the Bohr effect), a rise in temperature and increased 2,3-DPG. Breathing is under fine control through chemoreceptors; the central receptors on the ventrolateral surface of the medulla respond to the rise in H+ ions in the cerebrospinal fluid resulting from PaCO2 crossing the blood-brain barrier, whereas the peripheral receptors in the Carotid and aortic bodies respond to arterial hypoxaemia, and their activity and discharge rise sharply when PaO2 falls below 60 mm Hg.
- Functional residual capacity equals ERV + RV and is not measured by simple Spirometry, and normal lung compliance is 200 mL/cm H2O.
- The V/Q ratio is highest at the apex of the lung and lowest at the base.
- Hypoxaemia caused by an absolute shunt cannot be fully abolished by giving 100% oxygen.
- The normal P50 is 26.8 mm Hg, and the curve shifts to the right with increased acidity, PCO2, temperature and 2,3-DPG.
- The peripheral receptors are strongly stimulated when PaO2 falls below 60 mm Hg, whereas the central receptors respond to H+ in the cerebrospinal fluid.
Sources
- West's Respiratory Physiology: The Essentials, pp. 15–17
- West's Respiratory Physiology, p. 112
- West's Respiratory Physiology, pp. 74–76
- West's Respiratory Physiology, pp. 22–23
- West's Respiratory Physiology, pp. 68–70
- West's Respiratory Physiology, pp. 89–91
- West's Respiratory Physiology, pp. 91–92
- West's Respiratory Physiology, pp. 52–54
- West's Respiratory Physiology, pp. 146–147
- West's Respiratory Physiology, pp. 147–149
Test yourself: 4 questions on this topic and many more →
Educational content for healthcare staff and students. It does not replace clinical judgement or your hospital protocol; check any dose against the reference and local guidance before use.